Measurement of the SRE and KEWB Prompt Neutron Lifetime Using Random Noise and Reactor Oscillation Techniques

Measurement of the SRE and KEWB Prompt Neutron Lifetime Using Random Noise and Reactor Oscillation Techniques
Title Measurement of the SRE and KEWB Prompt Neutron Lifetime Using Random Noise and Reactor Oscillation Techniques PDF eBook
Author C. W. Griffin
Publisher
Total Pages 38
Release 1959
Genre Neutrons
ISBN

Download Measurement of the SRE and KEWB Prompt Neutron Lifetime Using Random Noise and Reactor Oscillation Techniques Book in PDF, Epub and Kindle

Measurement of the Sre and Kewb Prompt Neutron Lifetime Using Random Noise and Reactor Oscillation Techniques

Measurement of the Sre and Kewb Prompt Neutron Lifetime Using Random Noise and Reactor Oscillation Techniques
Title Measurement of the Sre and Kewb Prompt Neutron Lifetime Using Random Noise and Reactor Oscillation Techniques PDF eBook
Author
Publisher
Total Pages
Release 1959
Genre
ISBN

Download Measurement of the Sre and Kewb Prompt Neutron Lifetime Using Random Noise and Reactor Oscillation Techniques Book in PDF, Epub and Kindle

The prompt neutron lifetime of the SRE was measured by both the oscillation and random noise techniques. Measurement by use of the oscillation technique gave a prompt neutron lifetime of (5 25 plus or minus 0 35) x 10/sup - 4/ sec for a calculated beta of 7 x 10−3. The measured noise response indicated a lifetime of (5.25 plus or minus 0.7) x 10−4 sec. Both measured values are in agreement with the calculated value of 5 x 10−4 sec. Four experiments utilizing the noise analysis technique were performed to determine the prompt neutron lifetime of the KEWB. All four experiments gave results which agreed within 3%, For an estimated beta of 8 x 10−3, the measured value obtained was (7.8 plus or minus 0.3) x 10−5 sec. This is in reasonable agreement with both the energy independert calculated value of 6.6 x 10−5 see and the value of 6.2 x 10−5 sec obtained from the experimental inhour equation The oscillation technique has been found to be better suited for lifetime determinations in reactors where the prompt neutron break frequency is less than 5 cps. Reactor noise analysis is more suitable for reactors which have prompt neutron lifetime break frequencies above 20 cps. (auth).

Civilian Power Reactor Program

Civilian Power Reactor Program
Title Civilian Power Reactor Program PDF eBook
Author U.S. Atomic Energy Commission
Publisher
Total Pages 72
Release 1960
Genre Nuclear industry
ISBN

Download Civilian Power Reactor Program Book in PDF, Epub and Kindle

Nuclear Safety

Nuclear Safety
Title Nuclear Safety PDF eBook
Author
Publisher
Total Pages 1248
Release 1965
Genre Nuclear engineering
ISBN

Download Nuclear Safety Book in PDF, Epub and Kindle

On the Direct Measurement of the Power Spectral Density of Nuclear Reactor Fluctuations

On the Direct Measurement of the Power Spectral Density of Nuclear Reactor Fluctuations
Title On the Direct Measurement of the Power Spectral Density of Nuclear Reactor Fluctuations PDF eBook
Author Thomas L. Boennighausen
Publisher
Total Pages 110
Release 1964
Genre Neutrons
ISBN

Download On the Direct Measurement of the Power Spectral Density of Nuclear Reactor Fluctuations Book in PDF, Epub and Kindle

Measurement of Zero Power Frequency Response of the SRE

Measurement of Zero Power Frequency Response of the SRE
Title Measurement of Zero Power Frequency Response of the SRE PDF eBook
Author J. G. Lundholm
Publisher
Total Pages 62
Release 1960
Genre Nuclear reactors
ISBN

Download Measurement of Zero Power Frequency Response of the SRE Book in PDF, Epub and Kindle

List

List
Title List PDF eBook
Author
Publisher
Total Pages 564
Release 1948
Genre Nuclear energy
ISBN

Download List Book in PDF, Epub and Kindle